Product Specifications

  • SCSI bus termination is provided on the main board

  • Single Board computers have two 96-position DIN connectors, P1 AND P2

  • All models have a 20-pin connector mounted behind the front panel.

  • The MVME166 has a 68-pin mini D ribbon shielded connector for the SCSI bus interface and a 100-pin mini D ribbon shielded connector for serial ports, Ethernet, and printer.

  • Power sources are fused on the main board.

Manufactured by Motorola. Refurbished in good condition.

The Motorola MVME166-015A is a single board computer. SBCs provide mass storage subsystems through the industry-standard SCSI bus. These subsystems may include hard and floppy disk drives, streaming tape drives, and other mass storage devices. The SCSI interface is implemented using the NCR 53C710 SCSI I/O Controller. The SCSI bus termination is provided on the main board. The terminators are enabled/disabled by a jumper. If the SCSI bus ends at the MVME166, the SCSI terminators must be enabled by installing the jumper. SBCs include many resources for the local processor. These include tick timers, software programmable hardware interrupts, watchdog timer, and Local Bus time-out. Four 32-bit programmable tick timers with 1 msec resolution are provided, two in the VMEchip2 and two in the PCCchip2. The tick timers can be programmed to generate periodic interrupts to the processor. A watchdog timer function is provided in the VMEchip2. When the watchdog timer is enabled, it must be reset by software within the programmed time or it times out. The watchdog timer can be programmed to generate a SYSRESET signal, local reset signal, or board fail signal if it times out. Eight software-programmable hardware interrupts are provided by the VMEchip2. These interrupts allow software to create a hardware interrupt. The Single Board Computers provide a time-out function for the Local Bus. When the timer is enabled and a Local Bus access times out, a Transfer Error Acknowledge (TEA) signal is sent to the Local Bus master. The time-out value is selectable by software for 8 msec, 64 msec, 256 msec, or infinite. The Local Bus timer does not operate during VMEbus or VSB bound cycles. VMEbus bound cycles are timed by the VMEbus access timer and the VMEbus global timer. VSB bound cycles are timed by the VSB access timer, the VSB transfer timer, and if its serial arbiter is enabled, by the VSB arbitration timer.

SKUE15-0

Qty 1

Alternative P/N #: MVME166-015A, MVME 166 015A, MVME166 015A, MVME 166-15A


Product Manual

MVME166 DS, MVME166 MANUAL


Product Images

Product Video